Product Name: Corrosion Inhibitor for Primary-Side Closed-Loop Cooling Systems
Model: SGR0841
Description: This product is a specialized corrosion inhibitor designed for the primary-side circulating coolant in closed-loop liquid cooling systems—specifically those characterized by a sealed, airtight design, minimal make-up water requirements, and low discharge/blowdown. Formulated with a blend of organic, multi-component corrosion inhibitors, it is free from heavy metals and toxic or hazardous substances. It is environmentally friendly and exhibits exceptional stability.
Key Ingredients: Molybdates, tungstates, silicates, dispersants, non-ferrous metal protectants, and other additives.
Physical and Chemical Specifications:
Parameter | Specification |
Appearance | Colorless, pale yellow, or brownish-yellow liquid |
Density (20°C) g/cm³ | ≥ 1.05 |
pH Value (1% aqueous solution) | ≥ 8.0 |
Performance:
① Specifically engineered for closed-loop systems; offers long-term stability. Tailored for sealed, non-aerated circulating environments, the product features extremely low consumption rates and high durability. It does not volatilize or decompose, eliminating the need for frequent replenishment and perfectly aligning with the low-loss, long-cycle operational requirements of closed-loop systems. ② Multi-material, comprehensive corrosion protection: Specifically designed for liquid cooling systems containing various materials, it provides excellent passivation and protection for carbon steel piping, stainless steel heat exchangers, copper heat-exchange components, and aluminum alloy cold plates. It effectively mitigates galvanic corrosion—a common issue when multiple materials are used together—offering superior corrosion inhibition.
③ Trace-level scale inhibition and impurity control: It stabilizes trace calcium, magnesium, and iron ions in the water, preventing the accumulation of impurities and the formation of micro-scale deposits during long-term circulation in closed-loop systems. This avoids scaling on heat-exchange surfaces and the narrowing of pipe diameters, ensuring consistent heat-exchange efficiency.
④ Low electrical conductivity and high compatibility: Featuring a low-ion formulation, it does not cause abnormal spikes in water conductivity upon dosing. It meets the stringent requirements for high-precision cooling and low-conductivity water quality in computing centers, ensuring the reliable operation of sensitive equipment.
⑤ High temperature resistance and excellent circulation stability: Suitable for the full range of standard operating temperatures in closed-loop systems. It remains stable—without precipitation, sedimentation, or loss of efficacy—under both high and low-temperature cycling conditions. It prevents the formation of gels or biofilms during long-term operation, maintaining high system cleanliness.
⑥ Eco-friendly and safe: Free from heavy metals (such as chromium, lead, and mercury) and other toxic or hazardous substances; it produces no strong, irritating odors.
Applications: Specifically designed for the primary-side closed-loop cooling systems of computing centers and data centers. It is compatible with systems using pure water, low-hardness softened water, or tap water as the cooling medium, effectively meeting the water treatment requirements for the long-term, stable operation of large-scale computing clusters.
Usage:
Dosage depends on water quality parameters and process conditions. It is recommended to add 500–1000 mg/L (0.5–1.0 kg/m³) based on the volume of make-up water. The system should ideally be operated under slightly alkaline conditions. Packaging, Storage, and Transportation: Packaged in 5kg, 25kg, 200kg, or 1000kg plastic drums. Store in a cool, dry place; the shelf life is twelve months. Handle with care during transport and avoid impacts.